AJCN Tufts Nutrition Symposium, Boston Sept 24-26
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vobecky, J. S.
Right arrow Articles by Blanchard, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vobecky, J. S.
Right arrow Articles by Blanchard, R.
Agricola
Right arrow Articles by Vobecky, J. S.
Right arrow Articles by Blanchard, R.

American Journal of Clinical Nutrition, Vol 29, 766-771, Copyright © 1976 by The American Society for Clinical Nutrition, Inc


ORIGINAL RESEARCH COMMUNICATIONS

Vitamin E and C levels in infants during the first year of life

JS Vobecky, J Vobecky, D Shapcott and R Blanchard

The considerably lower vitamin E level found in cord blood and in newborns at birth than those found in the venous blood of mothers at delivery are not yet fully explained. In a group of 217 not selected newborns, we attempted to establish the relation between vitamin E and C levels at delivery and the changes during the first year of life. The mean serum vitamin E level rose from 0.37 mg/ml at 3 days to 0.80 mg/100 ml at 6 months and to 0.72 mg/100 ml at 12 months. On the other hand vitamin C mean levels lowered from 0.93 mg/100 ml in cord blood to 0.77 mg/100 ml at 6 months and to 0.73 mg/100 ml at 12 months. The rise of vitamin E values could be explained by the early use of infant solid foods with high vitamin and mineral content and by the increase of serum lipoproteins. Except at 3 days after delivery there were no individual values of serum vitamin E below the acceptable 0.35 mg/100 ml limit. However, serum vitamin C levels compatible with a moderate risk were very often observed, i.e., in 27.1% of infants at 6 months and in 30.5% at 1 year. Thus, vitamin E intake in infants was satisfactory with the usual diet but not vitamin C for which blood levels were not adequate. In view of these findings it appears necessary to evaluate periodically the vitamin E as well as vitamin C status in the infant population.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1976 by The American Society for Nutrition