AJCN North Carolina Research Campus
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ellis, K. J
Right arrow Articles by Heird, W. C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ellis, K. J
Right arrow Articles by Heird, W. C
Agricola
Right arrow Articles by Ellis, K. J
Right arrow Articles by Heird, W. C
American Journal of Clinical Nutrition, Vol. 85, No. 1, 90-95, January 2007
© 2007 American Society for Nutrition


ORIGINAL RESEARCH COMMUNICATION

Body-composition assessment in infancy: air-displacement plethysmography compared with a reference 4-compartment model1,2,3,4

Kenneth J Ellis, Manjiang Yao, Roman J Shypailo, Alessandro Urlando, William W Wong and William C Heird

1 From the USDA-ARS Children's Nutrition Research Center, Department of Pediatrics, Baylor College of Medicine, Houston, Texas (KJE, RJS, WWW, and WCH), and Life Measurement Inc, Concord, CA (MY and AU)

Background: A better understanding of the associations of early infant nutrition and growth with adult health requires accurate assessment of body composition in infancy.

Objective: This study evaluated the performance of an infant-sized air-displacement plethysmograph (PEA POD Infant Body Composition System) for the measurement of body composition in infants.

Design: Healthy infants (n = 49; age: 1.7–23.0 wk; weight: 2.7–7.1 kg) were examined with the PEA POD system. Reference values for percentage body fat (%BF) were obtained from a 4-compartment (4-C) body-composition model, which was based on measurements of total body water, bone mineral content, and total body potassium.

Results: Mean (±SD) reproducibility of %BF values obtained with the PEA POD system was 0.4 ± 1.3%. Mean %BF obtained with the PEA POD system (16.9 ± 6.5%) did not differ significantly from that obtained with the 4-C model (16.3 ± 7.2%), and the regression between %BF for the 4-C model and that for the PEA POD system (R2= 0.73, SEE = 3.7%BF) did not deviate significantly from the line of identity (y = x).

Conclusions: The PEA POD system provided a reliable, accurate, and immediate assessment of %BF in infants. Because of its ease of use, good precision, minimum safety concerns, and bedside accessibility, the PEA POD system is highly suitable for monitoring changes in body composition during infant growth in both the research and clinical settings.

Key Words: Body composition • infants • air-displacement plethysmography • 4-compartment reference model • dual-energy X-ray absorptiometry







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by The American Society for Nutrition