|
|
||||||||
ORIGINAL RESEARCH COMMUNICATION |
1 From the Departments of Ophthalmology (CS, CG, and JSW) and Internal Medicine (EO-M, BMM, and CEC), School of Medicine, University of California, Davis.
2 Supported by the Cystic Fibrosis Foundation, Hoffmann-La Roche Inc, the National Institute on Aging (AG04058), the Research to Prevent Blindness Jules and Doris Stein Professorship, Klee-Stiftung, Frankfurt aM, and the Studienstiftung des deutschen Volkes (German Scholarship Foundation). The all-trans zeaxanthin used was a gift from NI Krinsky (Tufts University, USDA, Boston), and the all-trans lycopene used was a gift from Hoffmann-La Roche (Basel, Switzerland). 3 Address reprint requests to JS Werner, Department of Ophthalmology and Section of Neurobiology, Physiology and Behavior, 4860 Y Street, Suite 2400, Sacramento, CA 95817. E-mail: jswerner{at}ucdavis.edu.
| ABSTRACT |
|---|
|
|
|---|
Objectives: Our aims were to determine plasma carotenoid concentrations, determine absorption and distribution of macular pigment, and assess retinal health and visual function in CF patients.
Design: In 10 adult CF patients (ages 2147 y) and 10 age- and sex-matched healthy control subjects, we measured macular pigment density in vivo, measured serum lutein and zeaxanthin concentrations, and comprehensively assessed visual performance (including contrast sensitivity, color discrimination, and retinal function) under conditions of daylight illumination.
Results: Serum lutein and zeaxanthin were significantly reduced (P < 0.005) in CF patients (
± SD: 87 ± 36.1 and 27 ± 15.8 nmol/L, respectively) compared with control subjects (190 ± 72.1 and 75 ± 23.6 nmol/L, respectively). Although macular pigment optical density was significantly lower (P < 0.0001) in the CF group (0.24 ± 0.11) than in the control group (0.53 ± 0.12), no significant differences in visual function were observed.
Conclusions: Adults with CF have dramatically low serum and macular concentrations of carotenoids (lutein and zeaxanthin), but their ocular status and visual function are surprisingly good. The clinical implications of low plasma concentrations of carotenoids in CF are yet to be clarified.
Key Words: Carotenoids cystic fibrosis lutein zeaxanthin macular pigment color vision contrast sensitivity electroretinogram
| INTRODUCTION |
|---|
|
|
|---|
The persistent infection and inflammation at airway surfaces continuously subjects CF patients to oxidative stress (911), especially during pulmonary exacerbations (12, 13). These oxidative processes can be expected to increase antioxidant micronutrient consumption. Because carotenoids are antioxidant micronutrients (14, 15), an increased carotenoid consumption caused by chronic respiratory inflammation can be expected to compound the deficiencies.
Two carotenoids, lutein and zeaxanthin, specifically accumulate in the macula (16, 17), the area of the retina responsible for maximal visual resolution. These molecules, which give the macula a yellow-orange color because of their absorption of short-wavelength light, are believed to play a major role in protecting retinal constituents from free radicals, both by the absorption of the highly phototoxic effects of short-wavelength light and by their free radical scavenging protective antioxidant properties (1619). Decreased plasma concentrations of these pigments are associated with an increased incidence of macular degeneration (20), although it is unclear whether concentrations of these carotenoids in the eye directly relate to the risk of retinal disease (21). More subtle than frank macular degeneration are the losses in sensitivity of cone photoreceptors associated with normal aging (22). A high amount of macular pigment might protect the retina from age-related loss in cone sensitivity (23), but alternative interpretations have been offered (22). If macular pigment does forestall the effects of normal aging, one might expect that CF patients with chronically reduced macular pigment optical density (MPOD) would exhibit an acceleration of normal age-related changes in visual function.
The major objective of this study was to assess plasma and retinal concentrations of lutein and zeaxanthin, the main macular carotenoids, and to evaluate the status of visual performance in a group of young adult CF patients. It was hypothesized that the expected low serum concentrations of carotenoids would cause a decreased retinal carotenoid content that, in turn, could cause subclinical manifestations of visual abnormalities as have been reported in previous studies of ocular health in CF (24, 25).
| SUBJECTS AND METHODS |
|---|
|
|
|---|
-tocopherol concentrations on the basis of a routine chemistry panel for CF. One subject had undergone a lung transplantation. None of the subjects had symptoms of visual dysfunction other than refractive errors and presbyopia. After the initial eye examination, the patients chose one test eye to be used for more extensive testing; in most cases, the right eye was chosen.
|
Measurement of carotenoid concentrations
Serum concentrations of ß-carotene and
-tocopherol were routinely available as part of our yearly assessments of CF patients and are as reported in Table 1
. Lycopene, as an additional indicator of carotenoid uptake, was measured on the day of eye examination, as were lutein and zeaxanthin as the major components of the macular pigment. Blood and plasma samples were covered to reduce light exposure during handling and were frozen at 70° within 30 min of collection until analyzed.
For these latter 3 carotenoid determinations, liquid-liquid carotenoid extraction of plasma samples was performed with ethanol n-hexane containing 0.05% butylated hydroxytoluene as previously described (27). After evaporation of the hexane layers, the residue was redissolved in 160 µL methanol:THF (50:50) and analyzed by reversed-phase HPLC. The carotenoids were separated by gradient elution with the use of a C30 YMC carotenoid column (5 FM, 250 x 4.6 mm; Waters, Milford, MA) and detected at 450 nm. The column was calibrated for retention times and quantification with the use of external calibration plots prepared from crystalline lutein (Sigma, St Louis), all-trans zeaxanthin, and all-trans lycopene.
Eye examination
All subjects received a complete optometric or ophthalmologic examination to detect the presence of retinal disease and abnormal ocular media. This included a slit-lamp examination and direct and indirect ophthalmoscopy. Color stereo fundus photographs of the macula and optic disc (Early Treatment Diabetic Retinopathy Study fields 1 and 2) were evaluated by a retinal specialist using a stereo viewer. Intraocular pressure was
22 mm Hg.
Optical density and distribution of macular pigment
The macular pigment acts as a filter of short-wave (blue) light. By quantifying this filter effect, it is possible to assess the amount and distribution of macular pigment. The absorption and distribution of the macular pigment (at 15 min, 30 min, 1°, 1.75°, and 7° retinal eccentricity) were assessed by the psychophysical method of heterochromatic flicker photometry (22, 28). For this study we used the densitometer by Macular Metrics, Providence, RI (29). The stimulus consisted of a 10°, 3.0-cd/m2, 470-nm adapting background. Superimposed on the background was 1 of 5 test stimuli: 2 test spots of 15 and 30 min diameter, 2 circular rings of 1° and 1.75°, and a 2° spot for the peripheral measurement. The test stimuli were composed of 2 narrow-band lights (from light-emitting diodes) having dominant wavelengths of 460 and 550 nm, which were alternated in square-wave counterphase at 1525 Hz for the 4 central stimuli and 712 Hz for the peripheral one. The flicker frequency was optimized for each subject on the basis of preliminary tests of flicker sensitivity. The subjects task was to eliminate or minimize the flicker by turning a dial that changed the ratio of light of the 2 wavelengths while maintaining a constant overall luminance. The subject viewed the stimulus in free view from a chin and forehead rest and with habitual refractive correction. Before each session, the light intensity from each wavelength was calibrated with a photodiode.
Spatial contrast sensitivity
Photopic contrast sensitivity was measured to provide an assessment of spatial vision under conditions of daylight illumination (photopic vision). This measure quantifies pattern vision for objects of any size including small objects as more traditionally measured by visual acuity. The subjects eyes were dilated and cyclopleged with 2.5% Phenylephrine and 0.5% Tropicamide (both from Bausch & Lomb Pharmaceuticals, Inc (Tampa, FL). Measurements of the contrast sensitivity function were obtained with vertically oriented sinusoidal gratings at 6 spatial frequencies (0.55, 1.125, 2.25, 4.5, 9, and 18 cycles/degree) and a space-average luminance of 45 cd/m2. The stimuli were presented on a computer monitor and viewed at optical infinity through an astronomical telescope designed so that the effective pupil area was constant across all subjects. Details of the apparatus and calibration are described by Schefrin et al (30). Thresholds, defined in terms of Michelson contrast, were measured by using a maximum-likelihood (31), 2-alternative, temporal forced-choice procedure in which subjects pressed a button to indicate in which of 2 intervals (defined by a computer voice) the stimulus was presented. Contrast thresholds for the test gratings corresponded to a detection probability of 75%, based on a logistic psychometric function.
Color discrimination
The perception of color is mediated by parallel neural pathways, which begin with the 3 cone types maximally sensitive at short, middle, or long wavelengths. Discrimination of colors dominated by each of the 3 cone types is expressed as the protan, deutan, and tritan axes of the Cambridge Colour Test (Cambridge Research Systems, Cambridge, United Kingdom). Losses in the sensitivity of cone pathways has been associated with normal aging (22), and selective losses have been demonstrated in retinal and optic nerve disorders (32, 33). Unspecified color vision defects have been reported for CF patients (24). For this study, the Cambridge Colour Test was used to present Landolt C patterns (216 cd/m2) on a calibrated computer monitor by using a video board with 15-bit resolution. The subjects task was to detect the location of the gap in a Landolt C with the use of a 4-alternative forced choice based on the principles of pseudo-isochromatic plates (34). Discrimination thresholds were defined by the minimum chromatic contrast required for detection of stimuli varied in terms of the stimulation of short-wave (tritan), middle-wave (deutan), and long-wave (protan) sensitive cones.
Multifocal electroretinogram
Retinal function was assessed electrophysiologically by the multifocal electroretinogram (mfERG). As illustrated in Figure 1
, this technique permits the response at discrete retinal locations to be isolated and to detect retinal dysfunction that has not yet led to visible changes in the fundus or global decreases in visual performance. This technique is based on a cross-correlation between hexagonal black-and-white stimulus changes and the local response of the retina, thus reflecting the first stage of retinal processing (35). The stimulus consisted of 103 scaled hexagons (flashed pseudorandomly at intervals of 13.3 ms) and extended to a retinal area of
50° in diameter. The recording procedure was performed as published previously (36). First-order kernel responses were evaluated in each of the patients mfERGs. These responses were grouped into 6 concentric rings. Implicit times (latencies) of N1 (first negative trough) and P1 (first positive peak) and amplitudes P1-N1 (difference between P1 and N1) were analyzed for each of the 6 areas as indicated in Figure 1
. Amplitudes were measured on the response-density-scaled regional averages. Data were not compared with those of the control subjects, but rather with data from a more extensive age-matched control group of 10 subjects in each age decade (36), which formed the standard for our laboratory. Latencies within or <2 SDs of the control group were considered normal.
|
| RESULTS |
|---|
|
|
|---|
|
Macular pigment optical density
As shown in Figure 2
, MPOD was lower at all retinal locations in the CF patients than in the control group. In the central 15 min, where MPOD is highest, optical density was 0.24 ± 0.11 in the CF patients compared with 0.53 ± 0.12 in the control group. The spatial distribution of macular pigment is also shown in Figure 2
. A mixed between-within analysis of variance verified that there was a significant difference in MPOD between the CF patients and age-matched control subjects (P < 0.0001) and a significant difference in MPOD among the 4 retinal eccentricities. However, no significant interaction between the groups and retinal eccentricity was observed (P > 0.05).
|
0.15 at 15 min). However, there was one outlierthe one patient who had been taking a lutein-containing multivitamin supplement. As shown in Figure 3
|
|
100 for the protan and deutan axes and
150 for the tritan axis) (39). Control subject no. 1 was excluded from the statistical analysis of the test results because he was known to be deuteranomalous. The unpaired Students t test showed no significant difference between CF patients and control subjects for any of the 3 axes (protan axis: P = 0.729; deutan axis: P = 0.331; tritan axis: P = 0.645).
|
|
| DISCUSSION |
|---|
|
|
|---|
Plasma and retinal carotenoids
The mean serum concentrations of lutein and zeaxanthin (87 and 27 nmol/L, respectively) in CF patients represented 47% and 36%, respectively, of those in the collectively matched control subjects and were lower than the values found in the lowest quintile of concentrations in the third National Health and Nutrition Examination Survey (20). We also found a remarkably strong correlation between serum carotenoids and macular pigment for the patients and control subjects, which was consistent with the findings of an epidemiologic study of 280 adult volunteers whose serum concentrations of lutein and zeaxanthin correlated with MPOD values (40). Of special interest in this context are CF patient no. 7, who had been taking a lutein supplement and thus had high normal serum carotenoid concentrations and MPOD values, and CF patient no. 2, who had a smoking history and who consistently had very low carotenoid concentrations and a very low MPOD. Interestingly, smokers represent another group of patients that are known to have a high incidence of airway inflammation and reduced carotenoid concentrations (41).
The starting point of this investigation was the hypothesis that CF patients with known low carotenoid concentrations would have low ocular concentrations of the antioxidants lutein and zeaxanthin. These carotenoids have largely been thought to protect the retina from oxidative damage (21, 42, 43), so the question arose as to whether the lack of macular pigment would produce symptoms of increased oxidative stress such as those found in the degenerative retinal diseases. Although we found the low values for MPOD that we had expected, only one CF patient had retinal abnormalities, and this patients retinal responses were normal as assessed with the mfERG. The retinal vein occlusion observed in CF patient no. 7 was thought by retinal specialists to be due to a vascular rather than to an ocular incident and was probably caused by this patients uncontrolled hypertension secondary to the side effects of the transplantation medications being taken. This finding is in marked contrast with the findings of previous studies of CF patients, which reported loss of contrast sensitivity and color vision deficiencies (25) and abnormal electrophysiological findings (24, 44, 45).
The discrepancy between the findings of the current study and those of previous studies might be due to several factors. First, the clinical management of exocrine pancreatic insufficiency has improved in the past 2 decades. The focus on pancreatic enzyme replacement and high-dose supplements of vitamins such as ADEK clearly has helped prevent ocular symptoms of vitamin A deficiency such as night blindness and severe forms of xerophthalmia, as has been shown in previous studies (25). One study (45) reported an improvement in contrast sensitivity after high-dose vitamin A supplementation. Second, use of the broad-spectrum antibiotic chloramphenicol in CF patients has been reduced to almost nothing. This drug has long been known to cause intermittent and permanent optic nerve damage in CF patients (46) and might have contributed to the loss of contrast sensitivity and the unspecified color vision deficiencies reported in a previous study (24). Although we could not eliminate the possibility that our patients had been treated with chloramphenicol at some point, it seems reasonable to assume that they may have been exposed to less of it than were the adult participants of previous studies. A third factor contributing to the ocular health of our adult CF patients is the management of CF-related diabetes. Good blood sugar regulation might delay the onset of diabetic ocular manifestations that lead to cataract and diabetic retinopathy.
Methodologic limitations
Our results need to be interpreted with some caution because we only studied a small number of CF patients, and there was little ethnic and socioeconomic variance in this group. Our studies were cross-sectional and focused on an age group that seldom exhibits age-related maculopathy. Moreover, the CF patients had few risk factors for age-related maculopathy, such as elevated blood pressure (except for CF patient no. 7) or a severe degree of atherosclerosis, although 1 smoked and 3 had diabetes (47). Our previous work shows that the protocol used in this study included several measures that are sensitive to deficits associated with early development of age-related macular degeneration (48). On the other hand, the plasma and macular pigment concentrations of lutein and zeaxanthin were largely different between the CF patients and the control subjects in the current study. If inverse relations between concentrations of these 2 carotenoids and ocular and visual abnormalities were causal and strong, we hypothesized that with sensitive testing methods we might have been able to detect them.
Clinical implication
Although there is accumulating evidence that the consumption of high amounts of dietary antioxidant micronutrients is positively associated with both respiratory (49) and eye (50) health, and that carotenoid intakes (including lutein and zeaxanthin) contribute to this evidence, it is interesting to note that both the recent Institute of Medicine guidelines (50) and the consensus CF nutritional guidelines (2) issue no specific recommendations for healthy persons or CF patients regarding the consumption of carotenoid supplements or foods high in lutein and zeaxanthin. As the life span of CF patients continues to increase as a function of improved nutrition, better strategies for handling airway clearance, respiratory tract infections, and lung transplantation, it is predictable that CF patients may increasingly manifest the consequences of age-related diseases, including macular degeneration.
We concluded that serum and retinal lutein and zeaxanthin concentrations were dramatically low but there was no evidence of a loss in visual performance or compromised retinal health in adult CF patients receiving standard care for CF. It would be useful to conduct the same protocol used in this study in a larger group of CF patients studied longitudinally over a broader spectrum of the life span and with a focus on CF patients aged >50 y.
| ACKNOWLEDGMENTS |
|---|
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
L. Zhao and B. V. Sweet Lutein and zeaxanthin for macular degeneration Am. J. Health Syst. Pharm., July 1, 2008; 65(13): 1232 - 1238. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Ribaya-Mercado and J. B. Blumberg Lutein and Zeaxanthin and Their Potential Roles in Disease Prevention J. Am. Coll. Nutr., December 1, 2004; 23(suppl_6): 567S - 587S. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |